PRODUCT GUIDE
SPECIFICATION
Euco 700
03050 -
Specifier Notes: This product guide specification is written according to the Construction Specifications
Institute (CSI) 3-Part Format. The section must be carefully reviewed and edited by the Architect or
Engineer to meet the requirements of the project and local building code. Coordinate this section with
other specification sections and the drawings. Delete all “Specifier Notes” when editing this section.
SECTION 03155
FLOOR JOINT FILLER
Specifier Notes: This section covers Euclid “Euco 700” semi-rigid, industrial floor joint filler for interior
concrete construction and control joints.
ACI 302.1R, Paragraph 9.10.1 advises to defer joint filling and sealing as long as possible to minimize
the effects of shrinkage-related joint opening on the filler or sealant. If the joint should be filled before
most of the shrinkage has occurred, separation should be expected between the joint edge and the joint
filler, or within the joint filler itself.
ACI 302.1R, Paragraph 9.10.2 indicates semi-rigid epoxy fillers should be installed full-depth in saw-cut
joints, and at least 1 inch (50 mm) deep in formed joints. Consult Euclid for assistance in editing this
section for the specific application.
This product is also available as “Euco 700 Gel”, a standard-setting, thick-paste consistency material for
special applications. Consult Euclid for more information.
PART 1
GENERAL
1.1
SECTION INCLUDES
A.
Semi-rigid, industrial concrete floor joint filler.
1.2
RELATED SECTIONS
Specifier Notes: Edit the following list of related sections as required for the project. List other sections
with work directly related to this section.
A.
Section 03300 - Cast-in-Place Concrete.
1.3
REFERENCES
A.
ACI 302.1R - Guide for Concrete Floor and Slab Construction.
1
Euco 700
03050 - 2
B.
ASTM C 109 - Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube
Specimens).
C.
ASTM D 570 - Water Absorption of Plastics.
D.
ASTM D 638 - Tensile