S M A R T
S A F E
P R O D U C T I V E
R E L I A B L E
- Maximum energy production
- Resilient to dust, debris and shading
- Performance monitoring per module
- System availability greater than 99.8%
- No single point of system failure
- Quick & simple design, installation and management
- 24/7 monitoring and analysis
- Low voltage DC
- Reduced fire risk
The Enphase Energy Microinverter System improves energy harvest,
increases reliability, and dramatically simplifies design, installation and
management of solar power systems. The Enphase System includes the
microinverter, the Envoy Communications Gateway, and the web-based
Enlighten monitoring and analysis website.
E N P H A S E M I C R O I N V E R T E R
D 3 8 0
60 and 72 Cell Modules
208V
240V
208V
240V
D380-72-208-S11/2/3
D380-72-240-S11/2/3
Operating temperature range
Night time power consumption
Dimensions (WxHxD)
Weight
Cooling
Enclosure environmental rating
12.25” x 6.00” x 1.33”
6.25 lbs
Natural Convection – No Fans
Outdoor – NEMA 6
Peak inverter efficiency
CEC weighted efficiency
Nominal MPP tracking
MICROINVERTER TECHNICAL DATA
Communication
Warranty
Compliance
Powerline
15 Years
UL1741/IEEE1547, FCC Part 15 Class B
Input Data (DC)
Output Data (AC)
Efficiency
Mechanical Data
Features
230W
54V
22V – 40V
12A
10A
230W
54V
22V – 40V
28V/54V
28V/54V
12A
10A
-40ºC to +65ºC
-40ºC to +65ºC
50mW
50mW
Maximum output power
Nominal output current
Nominal voltage/range
Extended voltage/range
Nominal frequency/range
Extended frequency/range
Power factor
Maximum units per 20A branch
380W
1.8A
208V/183V-229V
208V/179V-232V
60.0/59.3-60.5
60.0/59.2-60.6
>0.95
15
380W
1.6A
240V/211V-264V
240V/206V-269V
60.0/59.3-60.5
60.0/59.2-60.6
>0.95
10
95.5%
95.0%
99.6%
95.5%
95.0%
99.6%
142-00007 REV 03
Recommended input power (STC)
The D380 “TwinPack” microinverters contain 2 independent DC inputs. The Input Data (DC) values below apply
to both DC Inputs A and B individually
Maximum input DC voltage
Peak power tracking voltage
Min./Max. start voltage
Max. DC short circui