61041334
MATERIAL SAFETY DATA SHEET
MEDICAL EMERGENCY ONLY, 24 HOUR SERVICE: 1-800-328-0026
MEDICAL CALLS FROM OUTSIDE OF THE USA: 612 292 4064 (USA)
ECOLAB PROFESSIONAL PRODUCTS
DIVISION OF ECOLAB INC.
ECOLAB CENTER, ST. PAUL, MN 55102
FOR PRODUCT INFORMATION, CALL: 1-800-247-5362
DATE OF ISSUE: DECEMBER 3, 1998
1.0 IDENTIFICATION /
PRODUCT NAME: CIDA - RINSE GEL
PRODUCT TYPE: LIQUID HAND SANITIZER
HAZARD RATING:
HEALTH - 1
FIRE - 3
REACTIVITY - 0
++ SARA 313 TOXIC CHEMICALS, IF PRESENT, ARE PRECEDED BY "#" ++
2.0 HAZARDOUS COMPONENTS /
(MG/M3)
% PEL TWA
ETHANOL (ETHYL ALCOHOL) 64-17-5 70 1900 1880
PEL = OSHA 8 HOUR AVERAGE IN AIR
TWA = ACGIH 8 HOUR AVERAGE IN AIR
3.0 PHYSICAL DATA /
APPEARANCE: BLUE GEL; CLEAN AND FRESH SCENT
SOLUBILITY IN WATER:
MIXES WITH WATER IN ALL PROPORTIONS.
pH: 6.8 - 7.35 (100%)
INITIAL BOILING POINT: NOT DETERMINED
SPECIFIC GRAVITY: 0.869
4.0 FIRE AND EXPLOSION DATA /
SPECIAL FIRE HAZARDS:
FLAMMABLE LIQUID. FLAMMABLE PRODUCT VAPORS ARE HEAVIER THAN AIR AND CAN TRAVEL
TO AN IGNITION SITE.
FIRE FIGHTING METHODS:
USE FOG, FOAM, FINE WATER SPRAY, DRY CHEMICAL OR CO2.
FLASH POINT:
75 DEG. F (TAG CLOSED CUP), FLAMMABLE.
5.0 REACTIVITY DATA /
STABILITY:
STABLE UNDER NORMAL CONDITIONS OF HANDLING.
CONDITIONS TO AVOID:
HIGH TEMPERATURES, HEAT, SPARKS, OPEN FLAME. AVOID EXPOSURE TO FLAMES OR SPARKS
SOON AFTER APPLICATION TO SKIN.
6.0 SPILL OR LEAK PROCEDURES / USE PROPER PROTECTIVE EQUIPMENT
CLEANUP:
REMOVE ALL IGNITION SOURCES. RINSE SMALL AMOUNTS TO SANITARY SEWER WHERE
POSSIBLE, OR MOP UP AND RINSE AREA THOROUGHLY WITH WATER.
WASTE DISPOSAL:
CONSULT STATE/LOCAL AUTHORITIES FOR LIMITS ON CHEMICAL WASTE DISPOSAL. UNUSED
PRODUCT IS IGNITABLE (D001) BY RCRA CRITERIA.
7.0 HEALTH HA ZARD DATA / CAUTION
EFFECTS OF OVEREXPOSURE TO CONCENTRATE:
EYES: MAY CAUSE IRRITATION.
IF SWALLOWED:
MAY CAUSE STOMACH DISTRESS, NAUSEA OR VOMITING.
IF INHALED: