HENRY COMPANY CANADA INC.
10 St-Pierre, Lachine, Quebec H8R 1N7
Tel.:(514) 364-5224 Fax:(514)364-7270
EMERGENCY TEL. NO.: (514) 364-5224
MATERIAL SAFETY DATA SHEET
WHMIS: B-3, D-2B
I - PRODUCT INFORMATION
PRODUCT NAME
Bakor 710-11 Summer / 710-11 Winter
PRODUCT TYPE
Asphalt/Solvent Cutback
PRODUCT USE
Used as a heavy duty protective coating on masonry or concrete
II - HAZARDOUS INGREDIENTS
INGREDIENTS
%
CAS #
EXPOSURE LIMITS
LD50/LC50(SPECIES & ROUTE)
Stoddard Solvent
30-60
8052-41-3
100 ppm, TLV
LD50(oral-rat) > 5000 mg/kg
LC50(inhal.-rat) > 5g/m3
III - PHYSICAL DATA
PHYSICAL [ ] GAS
ODOUR & APPEARANCE
ODOUR THRESHOLD (ppm)
STATE [x] LIQUID
Black liquid, petroleum odour.
Not available
[ ] SOLID
VOLATILE (VOL.)
VOC
VAPOUR PRESSURE (mm Hg)
VAPOUR DENSITY (AIR = 1)
EVAPORATION RATE (BuAc=1)
38 - 43% < 410 g/L 7 at 38°C
3.9
0.10-0.15
BOILING POINT (°C)
FREEZING POINT (°C)
SPEC. GRAVITY (WATER - 1)
DENSITY (g / ml)
150 - 204°C
Not applicable
0.93
0.93
SOLUBILITY (IN WATER)
COEF. OF WATER/OIL DIST.
pH
Insoluble
Not available
Not applicable
IV - FIRE & EXPLOSION HAZARD
FLAMMABILITY
[ X ] YES
CONDITIONS OF FLAMMABILITY
[ ] NO
Avoid excessive heat and open flames.
FLASH POINT (°C):
41°C
FLAMMABLE LIMITS (% VOLUME)
AUTO-IGNITION TEMP. (°C)
METHOD:
PMCC
LOWER:
1.0
UPPER:
6.0
245°C for solvent
TDG FLAMMABILITY CLASS
SENSITIVITY TO MECHANICAL IMPACT
SENSITIVITY TO STATIC DISCHARGE
Class 3, PG III
None
If product above flash point.
HAZARDOUS COMBUSTION
On burning some SO2 and traces of CO.
PRODUCTS
Main combustion products are H2O, CO2 and C (as heavy smoke).
MEANS OF EXTINCTION
Foam , carbon dioxide, dry chemicals, water spray (for small fires).
SPEC. FIRE FIGHTING PROCEDURES
Contain spill. Cover with extinguishing agents. Use water spray to cool fire-exposed containers.
Self-contained equipment and full protective clothing when fumes or smoke are present.
V - PREPARATION OF M.S.D.