EMC Testing
The state of the art facilities to conduct EMC testing as per IEC/EN standards have
been installed. The 3 meter ferrite tiled Anechoic Chamber from ETS Lindgren is
utilized for carrying out Radiated Emission and Radiated Immunity Testing to cover
large equipment/system. The EMI Receiver upto 26.5 GHZ from Rhode & Schawarz
can measure easily eighth harmonics for Radiated Emission measurement on 3GHz
servers and IT products. For smaller equipment GTEM Cell upto 3 GHz can generate
Field upto 100V/m. The laboratory is equipped withy whole range equipment and
accessories to carry out Emission and Immunity Tests as per IEC/EN Standards
mentioned EMC Directive. The laboratory has well trained engineers to help
manufacturer to test for CE Marking requirements.
. International
Federal Communication Commission USA For Part 15 &18
UL USA – Certification of Appointment as a TCB Laboratory
Saudi Arab Standards Organisation
National Accreditation
• National Accreditation for Testing and Calibration Laboratories (NABL) for
Quality System as per ISO/IEC 17025:2005
•
STQC Certification Services for EMC Mark
• Bureau of Indian Standards
Radiated Emission Test Setup of IT Products
Sr.
No.
Product
Parameter / Test
Applicable Standards
1
IT Products
Emission, Immunity
and Harmonics
CISPR 22 & CISPR 24,
IEC61000-3-2
EN 55022 & EN 55024,
FCC Part 15 & 18
2
Domestic
Appliances & Tools
Emission, Immunity
and Harmonics &
Flicker
CISPR14-1,CISPR14-1
IEC 61000-3-2,IEC
61000-3-3
EN 55014-1 & EN 55014-
2
3
Luminaries &
Lighting Equipment
Emission, Immunity,
Harmonics & Flicker
CISPR 15,IEC 61547,
IEC 61000-3-2,IEC
61000-3-3
EN 55015
4
TV Receiver &
associated eqpt
Emission & Immunity CISPR 13 & CISPR 20
EN 55013 & EN 55020
5
UPS
Emission & Immunity IEC 62040-2
6
Energy meter
Emission & Immunity IEC62053-11 & 21
7
Electronic Ballast Emission, Immunity,
Harmonics & Flicker
CISPR 15,IEC 61547,
IEC 61000-3-2,IEC
61000-3-3