3
4
1579
Attachment No.6
TID
CID
CATALYST
Three way catalyst function
P0420
01H
01H
Max.
1/128
P0440
05H
03H
Max.
1/128mm2
P1440
05H
03H
Max.
1/128mm2
EVAP control system purge flow monitoring
P1447
06H
83H
Min.
20mV
P0133
09H
04H
Max.
10ms
P0131
0AH
84H
Min.
10mV
P0130
0BH
04H
Max.
10mV
P0132
0CH
04H
Max.
10mV
P0134
0DH
04H
Max.
1s
P0139
19H
86H
Min.
10mV/500ms
P0137
1AH
86H
Min.
10mV
P0140
1BH
06H
Max.
10mV
P0138
1CH
06H
Max.
10mV
P0135
29H
08H
Max.
20mV
P0135
2AH
88H
Min.
20mV
P0141
2DH
0AH
Max.
20mV
P0141
2EH
8AH
Min.
20mV
P0400
31H
8CH
Min.
1
P0400
32H
8CH
Min.
1
P0400
33H
8CH
Min.
1
P0400
34H
8CH
Min.
1
P1402
35H
0CH
Max.
1
P0402
36H
0CH
Max.
1count
P0402
37H
8CH
Min.
1count
TEST VALUE AND TEST LIMIT (GST ONLY — NOT APPLICABLE TO CONSULT-II)
The following is the information specified in Mode 6 of SAE J1979.
The test value is a parameter used to determine whether a system/circuit diagnostic test is “OK” or “NG” while
Test value
(GST display)
Test limit
Conversion
being monitored by the ECM during self-diagnosis. The test limit is a reference value which is specified as the
maximum or minimum value and is compared with the test value being monitored.
Items for which these data (test value and test limit) are displayed are the same as SRT code items.
These data (test value and test limit) are specified by Test ID (TID) and Component ID (CID) and can be dis-
played on the GST screen.
SRT item
Self-diagnostic test item
DTC
EVAP SYSTEM
EVAP control system (Small leak)
HO2S
Heated oxygen sensor 1
Heated oxygen sensor 2
HO2S HTR
Heated oxygen sensor 1 heater
Heated oxygen sensor 2 heater
EGR SYSTEM
EGR function
EGRC-BPT valve function
5
6
7
8
9
10
11
12
13
14
15
16
17
Thank you very much