PRODUCT NAME:
PF 152 ONE STEP FILL AND FINISH
INFORMATION TELEPHONE NUMBER:
(800) 387-7981
CANUTEC EMERGENCY TELEPHONE NUMBER:
(613) 996-6666
NFPA CODES:
Health
2
PRODUCT USE:
WHMIS CLASSIFICATION:
Flammability
3
B2, D2A, D2B
Instability
2
% BY WT
INGREDIENT
VAPOUR PRESSURE @ 20C
Styrene
ACGIH TLV-TWA
ppm
ACGIH TVL-STEL
ppm
OSHA PEL-TWA
ppm
OSHA PEL-C
ppm
LC50 (TVL)
ppm
LD50 (ORAL)
mg/kg
LC50 (DERMAL)
Not available
Not available
SPECIFIC GRAVITY:
Not Available
SOLUBILITY IN WATER:
Not available
VOLATILE ORGANIC COMPOUNDS:
Heavier than air
Unreacted: 196 g/l - 1.63 lbs/US gal
METHOD USED:
SETA FLASH closed cup
1.1 (styrene)
6.1 (styrene)
X
CARBON DIOXIDE
X
FOAM
X
FOG SPRAY
X
DRY CHEMICAL
WATER STREAM
OTHER (SEE SPECIAL PROCEDURES)
SPECIAL FIREFIGHTING PROCEDURES:
10-30 100-42-5
SECTION 1 - PRODUCT IDENTIFICATION AND USE
MATERIAL SAFETY DATA SHEET
Pro Form Products Ltd.
604 McGeachie Drive,
Milton, Ontario Canada, L9T 3Y5
C.A.S. #
SECTION 2 - HAZARDOUS INGREDIENTS
Thursday, January 29, 2004
Repair Product
MANUFACTURED
AND SUPPLIED BY:
40
100
5640
4.5 mmHg
20
200
Paste with aromatic odour of styrene monomer
VAPOUR DENSITY:
APPEARANCE:
EVAPORATION RATE:
Reacted: 4.4 g/l -0.036 lbs/US gal
BOILING POINT:
MELTING POINT:
5000
SECTION 3 - PHYSICAL DATA
0.9 - 1.7
Negligible
32C (89.6F) styrene
UPPER FLAMMABLE LIMIT (% BY VOLUME):
EXTINGUISHING METHOD:
Containers may explode when exposed to extreme heat. Vapours are heavier than air and collect in low-lying
areas. Vapours can travel to a source of ignition and flash back causing explosion and/or fire.
UNUSUAL FIRE AND EXPLOSION HAZARDS:
At elevated temperatures, such as may occur during a fire, rapid polymerization may take place. If this occurs in
a closed container, the container may explode.
FLASHPOINT:
Flammable. Conditions to avoid; Ignition sources, excessive heat, open flame and sparks.
SECTION 4 - FIRE AND EXPLOSION DATA
Full protective equipment including self-contained breathing apparatus should be used. Water spray may be
ineffective. If