May 2008
Page 1 of 3
MATERIAL SAFETY DATA SHEET
MAY BE USED TO COMPLY WITH OSHA’S HAZARD COMMUNICATION STANDARD, 29 CFR 1910.1200 AND
SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT (SARA) OF 1986 PUBLIC LAW 99-499.
STANDARD SHOULD BE CONSULTED FOR SPECIFIC REQUIREMENTS.
SECTION I (IDENTIFICATION)
MANUFACTURER/
EUTECTIC CORPORATION
TELEPHONE NUMBER:
SUPPLIERS NAME: N94 W14355 Garwin Mace Drive
1-800-558-8524
Menomonee Falls, WI 53051 USA
PRODUCT NAME:
EUTECTOR FLUX 9000
PRODUCT CLASSIFICATION:
Flux (Green Paste)
SECTION II (HAZARDOUS INGREDIENTS/IDENTITY INFORMATION)
IMPORTANT: This section covers the materials from which these products are manufactured. The fumes and gases produced during
normal use of these products are covered in Section V. The term "Hazardous" in "Hazardous Ingredients" should not only be interpreted
as a term required and defined in OSHA Hazard Communication Standard (29 CFR Part 1910.1200), but also as defined by other
regulatory agencies. The chemicals or compounds subject to reporting under Title III, in Section 313, of the Superfund Amendments
and Reauthorization Act (SARA) are marked by the symbol #.
WARNING: This product contains or produces a chemical known to the State of California to cause birth defects (or other reproductive
harm) and cancer. (California Health & Safety Code 25249.5 et seq.)
CAS
Exposure Limit (mg/m3)
INGREDIENTS
NUMBER
OSHA PEL
ACGIH-TLV
Percent Ingredients (by weight)
Sodium Tetraborate
Decahydrate
1303-96-4
Not Listed
5
40 – 70
Boric Acid
10043-35-3
Not Listed
Not Listed
30 – 60
SECTION III (PHYSICAL DATA) – Green paste flux
SECTION IV (FIRE AND EXPLOSION HAZARD DATA)
Non-Flammable: Flames used for brazing or soldering can ignite combustibles. Refer to American National Standard Z49.1 for fire
prevention during welding/brazing. T