ELCB1
ELCB1 HS
Max. capacity (Emax)
A
B
C
D
E
F
G
H
J
K
j L
M
N
220 kg; 550 kg; 1.1 t; 1.76 t
133.4
30.2
30.7
57.7
15.4
76.2
25.4
1.7
13
3 m
20.6
M12
14.2
Special features
− Small dimensions
− Max. capacities: 220 kg ... 1.76 t
− Stainless steel
− Meets EMC standards (EN 45 501)
− Protection class IP 67 (ELCB1)
or IP 68 (ELCB1 HS)
Load cells
ELCB...
(white)
(black)
Excitation (+)
(red)
Excitation (−)
Signal (+)
(blue)
Signal (−)
Shield
(connected with housing)
Wiring code:
Dimensions (in mm; 1 mm= 0.03937 inches)
A
D
H
B
∅ L
N
M
K
J
J
G
F
E
C
H
B
N
C
B0978-4.1 en
Data Sheet
Specifications
Type
ELCB1
ELCB1 HS
Maximum capacity (Emax)
550 kg; 1.1 t; 1.76 t
220 kg; 550 kg; 1.1 t; 1.76 t
Accuracy class
1 %
1 %
Sensitivity (Cn)
mV/V
2 1 %
2 1 %
Temperature effect on sensitivity (TKC)
% of C / 10 K
0.4000
0.4000
Temperature effect on zero balance (TK0)
n
0.4000
0.4000
Hysteresis error (dhy)
0.1000
0.1000
Non-linearity (dlin)
% of Cn
0.1000
0.1000
Creep (dcr) over 30 min.
0.1000
0.1000
Input resistance (RLC)
Ω
> 350
> 350
Output resistance (R0)
344 2
344 2
Reference excitation voltage (Uref)
V
5
5
Nominal range of excitation voltage (BU)
0.5 ... 15
0.5 ... 15
Insulation resistance (Ris)
GΩ
> 5
> 5
Nominal temperature range (BT)
−10 ... +40 [+14 ... +104]
−10 ... +40 [+14 ... +104]
Service temperature range (Btu)
°C [°F]
−30 ... +70 [−22 ... +158]
−30 ... +70 [−22 ... +158]
Storage temperature range (Btl)
−50 ... +85 [−58 ... +185]
−50 ... +85 [−58 ... +185]
Safe load limit (EL)
150
150
Breaking load (Ed)
300
300
Lateral load limit (Elq)
% of Emax
100
100
Permissible dynamic load (Fsrel)
(vibration amplitude according to DIN 50100)
70
70
Deflection at Emax (snom), approx.
mm
0.5
0.5
Weight (G)
Emax 220 kg ... 1,76 t
kg
~ 0.9
~ 0.9
Protection class accord. to EN60529 (IEC529)
IP67
IP68
Material: Measuring element
Cable entry
Cable sheath
Application protection (sealing)
Stainless steel
Stainless steel
(Gasket: Neoprene)
TPE
Silicone
Stainless steel
Stainless steel
(Gasket: Neoprene)
TPE
hermetically welded