Loading ...
Global Do...
Science
MSDS
144
1
Try Now
Log In
Pricing
<p> MAGNAFLOC LT – 7996, LIQUID PRODUCT DISTRIBUTED BY / PRODUIT DISTRIBUÉ PAR Brenntag Canada Inc. WHMIS Number: 00065995 43 Jutland Road. Index: HCI5135/07A Toronto, Ontario Effective Date: 2007 March 14 M8Z 2G6 Date of Revision: 2007 March 14 (416) 259-8231 Website: http://www.brenntag.ca _______________________________________________________________________________________________ EMERGENCY TELEPHONE NUMBERS / EN CAS D'URGENCE Toronto, ON (416) 226-6117 Montréal, QC (514) 861-1211 Winnipeg, MB (204) 943-8827 Edmonton, AB (780) 424-1754 Calgary, AB (403) 263-8660 Vancouver, BC (604) 685-5036 _______________________________________________________________________________________________ This document consists of an English MSDS. Le présent document comprend une fiche signalétique en anglais. READ THE ENTIRE MSDS FOR THE COMPLETE HAZARD EVALUATION OF THIS PRODUCT. LIRE LA FICHE SIGNALÉTIQUE EN ENTIER POUR UNE ÉVALUATION COMPLÈTE DES DANGERS QUE REPRÉSENTE CE PRODUIT Page: 1 / 6 000000021833 Material Safety Data Sheet WHMIS / ANSI Z400.1-2004 Compliant Date / Revised: 03-14-2007 Release: 1.1 Product: MAGNAFLOC LT-7996 1. Identification of the Substance/Preparation and of the Company/Undertaking Company Information Company: Ciba Specialty Chemicals Canada Inc 2626 Argentia Road Mississauga, Ontario L5N 5N2 Canada Customer Service / Product Information: 1-866-679-2422 Emergency information Emergency 24-Hour Health/Environmental Phone: 24h: +1-800-873-1138 CANUTEC: (613) 996-6666 (24hrs) Product information Product: MAGNAFLOC LT-7996 Use: Coagulant. 2. Hazards Identification Emergency overview Signal word: CAUTION: ! Colour: straw yellow Appearance: liquid State of matter: liquid Odour: amine-like Health: This product has no known adverse effect on human health. Physical/Chemical hazards: Spills are very slippery. Potential health effects Primary routes of entry: Skin, Eyes, Inhalation, Ingestion Chronic exposure: Prolonged or repeated contact may cause eye and skin irritation. Inhalation of mist or vapor may cause irritation of the upper respiratory passages with coughing and discomfort. 3. Composition/Information on Ingredients This material does not contain any hazardous components that are reportable according to WHMIS criteria. 4. First-aid Measures Inhalation: Remove to fresh air, if not breathing give artificial respiration. If breathing is difficult, give oxygen and get immediate medical attention. Page: 2 / 6 000000021833 Material Safety Data Sheet WHMIS / ANSI Z400.1-2004 Compliant Date / Revised: 03-14-2007 Release: 1.1 Product: MAGNAFLOC LT-7996 Skin: If clothing is contaminated, remove and launder before reuse. After contact with skin, wash immediately with plenty of water and soap. Get medical attention if irritation occurs. Eyes: Immediately flush the eye(s) with lukewarm, gently flowing water for 15 minutes or until the chemical is removed. Get immediate medical attention if irritation persists. Ingestion: Do not induce vomiting. If vomiting occurs naturally, have casualty lean forward to reduce the risk of aspiration. Seek medical attention immediately. 5. Fire-fighting Measures Suitable extinguishing media: carbon dioxide, dry powder, foam, water fog Hazardous combustion products: Carbon-, nitrogen oxides, hydrogen chloride, ammonia. Hazards during fire-fighting: Standard procedure for chemical fires. Cool fire-exposed containers with water. Spills can cause very slippery conditions on floors. Restrict pedestrian and vehicular traffic in areas where slip hazard may exist. Protective equipment for fire-fighting: Wear self-contained breathing apparatus and chemical-protective clothing. 6. Accidental Release Measures Cleanup: Spills are very slippery. Pick up with inert absorbent material (e.g. sand, earth etc.). Place into approved waste containers. Wear suitable protective equipment. Should not be released into the environment. 7. Handling and Storage Handling General advice: As with all industrial chemicals, use good industrial practices when handling. Avoid eye, skin, and clothing contact. Do not inhale. Do not taste or swallow. Use only with adequate ventilation. Product may freeze; however, it should recover upon warming. Should freezing occur, warm slowly. Thawed product should be thoroughly mixed with low shear agitation prior to use. Storage General advice: Keep container tightly closed in a dry, cool and well-ventilated place. Sensitive to cold below 0°C (32°F). Temperature tolerance: FROST SENSITIVE PRODUCT > for industrial use only < Page: 3 / 6 000000021833 Material Safety Data Sheet WHMIS / ANSI Z400.1-2004 Compliant Date / Revised: 03-14-2007 Release: 1.1 Product: MAGNAFLOC LT-7996 8. Exposure Controls and Personal Protection Engineering Controls: Work in well ventilated areas. Do not breathe vapors or mist. Personal protective equipment Respiratory protection: Wear a NIOSH-certified respirator as necessary. Eye protection: Tightly fitting safety goggles (splash goggles) (EN 166) Body protection: Wear chemical resistant gloves and protective clothing. General safety and hygiene measures: Select additional protective equipment based upon potential for exposure., There are no OSHA or ACGIH exposure guidelines available for component(s) in this product., Eye wash station and safety shower should be available in immediate work area. 9. Physical and Chemical Properties Colour: straw yellow Form: liquid State of matter: liquid Odour: amine-like pH value: approx.6 Evaporation rate: Not tested Flash point: > 100 °C Self-ignition temperature: Not tested Melting point: < 0 °C Boiling point: > 100 °C Vapour pressure: Not tested Density: approx. 1.0 g/cm3 Vapour density: Not tested Partitioning coefficient n- octanol/water (log Pow): Not applicable Viscosity, dynamic: Not tested % Volatiles: not determined Solubility in water: miscible Solubility in other solvents: Not tested 10. Stability and Reactivity Stability: Stable. Conditions to avoid: Avoid temperature extremes, especially frost and freezing conditions. Substances to avoid: Strong oxidizing agents., May react slowly with iron, copper, and aluminium resulting in corrosion and discoloration of product. Possibility of Hazardous Reactions: No hazardous reactions known. Hazardous decomposition products: Hazardous decomposition products: No decomposition expected under normal storage conditions. Page: 4 / 6 000000021833 Material Safety Data Sheet WHMIS / ANSI Z400.1-2004 Compliant Date / Revised: 03-14-2007 Release: 1.1 Product: MAGNAFLOC LT-7996 11. Toxicological Information Acute oral toxicity: LD50 / oral / rat: > 2,000 mg/kg Acute inhalation toxicity: Not tested Acute dermal toxicity: dermal: Not tested Skin irritation: May cause skin irritation (Active Ingredient) Eye irritation: May cause eye irritation. (Active Ingredient) Skin Sensitization: Not tested Subchronic Toxicty: A six month study with rats at doses of 1000 mg/kg/day and 2000 mg/kg/day showed cellular effects in kidneys and lungs. Both test concentrations also reduced body weight gain. The No Effect dose is less than 1000mg/kg/day. Subacute Toxicity: not determined Chronic toxicity: not determined Genetic toxicity: Not determined. Carcinogenicity: None of the components in this product at concentrations greater than 0.1% are listed by IARC; NTP, OSHA or ACGIH as a carcinogen. Reproductive toxicity: not determined Developmental toxicity/teratogenicity: not determined 12. Ecological Information Toxicity to fish: 96 h/LC50: > 10 mg/l By analogy with a product of similar composition Toxicity to aquatic invertebrates: 48 h/EC50: > 10 mg/l By analogy with a product of similar composition Toxicity to aquatic plants: Not tested Page: 5 / 6 000000021833 Material Safety Data Sheet WHMIS / ANSI Z400.1-2004 Compliant Date / Revised: 03-14-2007 Release: 1.1 Product: MAGNAFLOC LT-7996 Toxicity to microorganisms: Not tested Biodegradation: Not tested Other ecotoxicological advice: This product contains polymer(s) that may be toxic to aquatic organisms when tested in pure (distilled) water. Toxicity is greatly reduced byparticles in natural water. 13. Disposal Considerations Waste disposal of substance: Dispose of in accordance with national, state and local regulations. Contaminated packaging: Empty containers or liners may retain product residues. Do not reuse empty containers. 14. Transport Information TDG (Canada) Road transport Special shipping information: Not classified as a dangerous good under transport regulations. International Air Transport Association (IATA) Special shipping information: Not classified as a dangerous good under transport regulations. International Maritime Dangerous Goods Code (IMDG) Special shipping information: Not classified as a dangerous good under transport regulations. 15. Regulatory Information Canada: Domestic Substances List (DSL): All components either exempt or listed on the DSL US: Toxic Substances Control Act (TSCA): All component(s) comprising this product are either exempt or listed on the TSCA inventory Canada Regulations Workplace Hazardous Materials Information System (WHMIS Classification): This product is not WHMIS controlled. Significant New Activity Conditions (SNAC): This product does not contain any components subject to a SNAC Notice. International Regulations Chemical Weapons Convention: This product does not contain any component(s) listed under the Chemical Weapons Convention Schedule of Chemicals. 16. Other Information Product Safety Contact: Prepared by: Ginette Rambié (905) 812-7280 Page: 6 / 6 000000021833 Material Safety Data Sheet WHMIS / ANSI Z400.1-2004 Compliant Date / Revised: 03-14-2007 Release: 1.1 Product: MAGNAFLOC LT-7996 Phone number of preparer: Date / Revised: 03-14-2007 This product has been classified in accordance with the hazard criteria of the Controlled Products Regulations and the MSDS contains all the information required by the Controlled Products Regulations. Disclaimer: The information contained herein is based upon data believed to be correct. However, no guarantee or warranty of any kind, expressed or implied, is made with respect to such data or information. The user is responsible for determining whether the product is suitable for its intended conditions of use. END OF DATA SHEET </p>