Impact of wind load as a marvel on structures, especially tall plans cant be unseen. Its major to ponder the deferred result of wind in style and appraisal of plans. The plan is explored for the gravity loads and besides for the equivalent loads for example wind load in zone ii Bhopal , zone iii Nagpur , zone iv Delhi , zone v Calcutta , zone vi Darbhanga .The structure is made on the thing known as staad.pro v8i. This appraisal is the assessment of the Reinforced strong cement multi story building G 10 . The codes utilized for the evaluations of Dead weight are IS 875 Part 1 1987 ,for live weight the code IS 875 Part 2 1987 and for the incorporates of wind power in various breeze zones are IS 875 fragment 3 1987.The deferred result of these appraisal shows the adjustment of forces, departures responses and weight of steel the proportion of partner material expected to negate equivalent loads will increase without a doubt. Amount of essential material expected to go against sidelong loads will augment profoundly. Subodh Kumar | Prof. Priyanka Dubey "Seismic Analysis & Design of Reinforced Concrete Multistory Building under Different Zone's" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-5 | Issue-6 , October 2021, URL: https://www.ijtsrd.com/papers/ijtsrd46404.pdf Paper URL : https://www.ijtsrd.com/engineering/civil-engineering/46404/seismic-analysis-and-design-of-reinforced-concrete-multistory-building-under-different-zone's/subodh-kumar
International Journal of Trend in Scientific Research and Development (IJTSRD)
Volume 5 Issue 6, September-October 2021 Available Online: www.ijtsrd.com e-ISSN: 2456 – 6470
@ IJTSRD | Unique Paper ID – IJTSRD46404 | Volume – 5 | Issue – 6 | Sep-Oct 2021
Page 264
Seismic Analysis & Design of Reinforced Concrete
Multistory Building under Different Zone’s
Subodh Kumar
1
, Prof. Priyanka Dubey
2
1Research Scholar, 2Assistant Professor,
1,2Department of Structural Engineering, Dr. A.P.J. Abdul Kalam University, Indore, Madhya Pradesh, India
ABSTRACT
Impact of wind load as a marvel on structures, especially tall plans
can't be unseen. It's major to ponder the deferred result of wind in
style and appraisal of plans. The plan is explored for the gravity loads
and besides for the equivalent loads for example wind load in zone-ii
(Bhopal), zone-iii (Nagpur), zone iv (Delhi), zone-v (Calcutta), zone-
vi (Darbhanga).The structure is made on the thing known as staad.pro
v8i. This appraisal is the assessment of the Reinforced strong cement
multi-story building (G+10). The codes utilized for the evaluations of
Dead weight are IS:875(Part 1)- 1987 ,for live weight the code IS
:875(Part 2)- 1987 and for the incorporates of wind power in various
breeze zones are IS :875 ( fragment 3) - 1987.The deferred result of
these appraisal shows the adjustment of forces, departures responses
and weight of steel the proportion of partner material expected to
negate equivalent loads will increase without a doubt. Amount of
essential material expected to go against sidelong loads will augment
profoundly.
KEYWORDS: wind zones. Gravity Load Analysis and Design, Wind
Load Analysis & Design, Comparison of wind intensity
How to cite this paper: Subodh Kumar |
Prof. Priyanka Dubey "Seismic Analysis
& Design of Reinforced Concrete
Multistory Building under Different
Zone’s" Published
in
International
Journal of Trend in
Scientific Research
and Development
(ijtsrd), ISSN: 2456-
6470, Vol