Tech-note
PN# TN105-2.DOC - 08-Feb-01 - Ver. 1.02
Page 1
UniOP MKDG-06
Low cost HMI unit with monochrome graphic LCD display.
Highlights
• Graphic monochrome
display
• 8 rows, 40 columns of text
• Downloadable fonts
• Scalable text
• 23 function keys
• 24 user LEDs
• ASCII keyboard
• Multilanguage project
capability
• Connection to bus systems
• New plastic bezel with flat
design
Technical data
Display
Monochrome LCD
Backlight
LED
Graphics
240x64 pixels
Display dimensions
127x34 mm
Rows/columns
8x40
Character height
-
Scalable fonts
Yes
User definable characters
256
Contrast regulation
Software
User memory
512 KB (64 reserved to the protocol)
User memory expansion
512 KB
Function keys
23
System keys
24
Touch screen
No
User LEDs
24
System LEDs
5
PC/Printer port
Yes
PLC port
RS-232, RS-422, RS-485, CL 20 mA
Aux port (fieldbus connection)
Yes, with optional module
B
A
R
Q
)
(
D
C
T
S
%
*
F
E
V
U
@
#
H
G
X
W
>
<
J
I
Z
Y
SP
L
K
/
.
BSP
N
M
;
,
2nd
P
O
?
:
U n iO P
S h i f t
7
8
9
4
1
5
2
0
6
3
!
r
Toll Free Phone: 877-378-0240
Toll Free Fax: 877-378-0249
sales@servo2go.com
www.servo2go.com
Sold & Serviced By:
Tech-note
PN# TN105-2.DOC - 08-Feb-01 - Ver. 1.02
Page 2
External keyboard port
No
Programming speed
9600 ÷ 38400 bps
Page size
32 rows
Number of variables per page
Unlimited
Recipe memory
16 KB
UniNet network
Client/Server
Alarms
1024
Event list
256
Alarm info page
Yes
Password
Yes
Battery
Yes
Hardware RTC
Yes
Screen saver
No
Buzzer
No
Fuse
2 A (user replaceable)
Power supply voltage
18 ÷ 30 VDC
Max power consumption at 24VDC ~ 400 mA
Max panel thickness
5 mm
Weight
Operating temperature
0 ÷ 50 °C
Storage temperature
-20 ÷ 70 °C
Operating and storage humidity
5 ÷ 95 % UR non-condensing
Protection class
IP-65 (front panel)
Front dimensions and cutout
Front dimensions LxH
220 x 176 mm
8.66 x 6.93 ”
Cutout AxB
207 x 163 mm
8.15 x 6.42 ”
Cutout depth – version –0045
76 mm
2.99 “
Cu